Different density measurement results between V15 and V16

Different density measurement results between V15 and V16

Problem/Question
When comparing density measurements between Ergosoft RIP 15 and Ergosoft 16, differences may occur. This is due to the newly added density specifications for the primary inks.

Solution/Work-Around
To change back to the default setting of Ergosoft RIP 15 please follow the step below:
  1. Open the "Application Defaults" under "Tools" in the menue bar
  2. Select "Spectrophotometer" in "Application" tab
  3. Set in the "Measurement Standards" field the "Density specification for primary inks:" from "Status E - ISO 5-3 (Default)" to "DIN 16536-2 (Legacy)"

Related Articles & Links

    • Related Articles

    • Missing Barbieri Measurement Tool Selection

      Problem/Question After an update to the current version 16, the Barbieri measurment tool is missing in the measuring tool selection. Since Barbieri has extremely enlarged its Gateway installer, we have decided to make it available as an additional ...
    • Calibration & Profile with White Ink as “User modified curve”

      Problem/Question “How to do a Calibration & Profiling with  White Ink underlay, using a User modified curve" Solution/Work-Around In order to do a Calibration & Profile with the White Ink underlay, there is a need to define how we want to manage the ...
    • Calibration & Profile with White Ink using “Legacy modes"

      Problem/Question “How to do a Calibration & Profiling with  White Ink underlay, using  Legacy Modes" Solution/Work-Around In order to do a Calibration & Profile with the White Ink underlay, there is a need to define how we want to manage the white ...
    • Deterioration in print quality after an ink changeover

      Problem/Question A deterioration in print quality is detected after an ink changeover. How can the print quality be restored? Solution/Work-Around Copy the PrintEnvironment used before an ink changeover and name it differently Remove the embedded ...
    • 0x1203 Error: Command failed: S1 when measuring with Barbieri Spectro LFP

      Problem/Question When attempting to measure and/or do the White calibration with the Barbieri Spectro LFP, the measuring head does not move and it gives out the error message "0x1203 Error: Command failed: S1". Solution/Work-Around This issue usually ...